Thermal Performance Experimental Study of Hot Wall in Cold Region

摘要:

文章预览

In order to satisfy the requirement of villages indoor thermal amenity in winter in cold district in north of china, thermal performance of level, vertical flue smoke organization form hot wall have been tested. The experiment use Testo flue gas analyzer, BES-C portable computer multi-channel data acquisition instrument, the infrared thermography and so on to acquire basic data of two type flue layouts hot wall. These parameters include smoke composition, the inport and export smoke temperature, smoke quantity, metope temperature of hot wall and so on. And then record the test data, calculate evaluation index of the thermal performance, which are metope temperature standard deviation, thermal inertia and heat efficiency, etc. According to the value of the heat efficiency, we can judge the thermal performance of two kind of hot walls. The test results shows that the heat efficiency of level flue smoke organization form is 68.9%, and the heat efficiency of vertical flue smoke organization form is 62.1%. The heat efficiency of hot wall in the form of level flue is higher, better meet the requirement of heating facilities in energy saving, residents thermal amenity.

信息:

期刊:

编辑:

Qing Yang, Li Hua Zhu, Jing Jing He, Zeng Feng Yan and Rui Ren

页数:

3711-3716

DOI:

10.4028/www.scientific.net/AMR.368-373.3711

引用:

H. G. Ren et al., "Thermal Performance Experimental Study of Hot Wall in Cold Region", Advanced Materials Research, Vols. 368-373, pp. 3711-3716, 2012

上线时间:

October 2011

输出:

价格:

$35.00

[1] DuanMuLin, ZhaoYang etc. Research and Assessment Method of Thermal Performance of Chinese Kang. Architectural science, (2009), 25 (12), In Chinese.

[2] XvHongBo, JiaoQingYu, XvGuoTang: The Research of The High Efficiency prefabricated and Combined-suspend Heatable Brick Bed. Journal of agricultural engineering, (1991), 27 (3) : 81 ~ 86, In Chinese.

[3] WangYi Nan, FengGeYu etc. Numerical Simulation of Thermal Environment of Kang, Radiators, Hotwall Heating Room. Architectural heat ventilation and air conditioning, (2009), 29 (3), In Chinese.

[4] ChenRongYao, LvLiang: The analysis of civil kang with kang thermal performance testing methods. Applied energy technology, (1985), 1 (1) : 36 ~ 40.

[5] ZhuangZhi: Smoke flow and thermal performance of Chinese Kangs. Dalian technology university, (2009), In Chinese.

[6] DuanMuLin, ZhaoYang etc. Experimental study on the thermal performance of Hot-wall type Kang. Architectural science, (2010), (2) , In Chinese.

[7] YuShui, FengGuoHui, LiGuoJian: Phase change energy storage kang technical analysis. Journal of ShenYang construction university, (2007), (supplement) : 202 ~ 204, In Chinese.

[8] LiuJianWei: Research on Integrated Thermal Inertia of Buildings. Tianjin: Environmental science and engineering institute in Tianjin university. (2007) , In Chinese.

[9] FangXiuMu: Building environment test technology. Beijing: China architecture industrial press. (2002), In Chinese.

[10] Information on http: /baike. baidu. com/view/337712. htm.

[11] LiangZhenShan, SuiXiuLan, LiuYiGong: Density calculation in flue gas velocity measurement. Electric power university in North China. (1995), 9, In Chinese.

[12] XvShengHua: Direct calculation method of smoke property . Suzhou silk tech. journal. (1999), 19(3) , In Chinese.

为了查看相关信息, 需 Login.